/config/local/sensor/{name}/channel

The A/D converter channel configuration of the named sensor.

Get /config/local/sensor/{name}/channel

SecurityApiKey
Request
path Parameters
name
required
string

The name of a sensor (L1-L3, Ldc, or S1-S30).

Example: S1
query Parameters
max-depth
integer >= 1

Limit output depth of the response. See Max-Depth.

Example: max-depth=2
filter
string

Response filter string. See Filter-Spec.

Example: filter={foo,bar}
Responses
200

Normal response.

401

Unauthorized response.

get/config/local/sensor/{name}/channel
Request samples
Response samples
application/json
{
  • "result": {
    },
  • "error": "Error message (present if an error occurred)."
}

Replace /config/local/sensor/{name}/channel

SecurityApiKey
Request
path Parameters
name
required
string

The name of a sensor (L1-L3, Ldc, or S1-S30).

Example: S1
Request Body schema: application/json
bias
number (configLocalSensorNameChannelBias)

The bias value (offset) to be added when converting an A/D converter sample to a physical quantity.

mode
string (configLocalSensorNameChannelMode)

The channel's acquisition mode. Possible values are:

  • integrate: The sample values are integrated over time.

  • normal: The sensor is operating in normal mode.

  • off: The sensor is not in use.

Enum: "off" "normal" "integrate"
scale
number (configLocalSensorNameChannelScale)

The scale value by which an A/D converter sample is to be divided to convert a sample to a physical quantity (the bias value is added to the sample before the scale is applied).

Responses
200

Normal response.

401

Unauthorized response.

put/config/local/sensor/{name}/channel
Request samples
application/json
{ }
Response samples
application/json
{
  • "status": "OK",
  • "error": "Error message (present if an error occurred)."
}

Update /config/local/sensor/{name}/channel

SecurityApiKey
Request
path Parameters
name
required
string

The name of a sensor (L1-L3, Ldc, or S1-S30).

Example: S1
Request Body schema: application/json
bias
number (configLocalSensorNameChannelBias)

The bias value (offset) to be added when converting an A/D converter sample to a physical quantity.

mode
string (configLocalSensorNameChannelMode)

The channel's acquisition mode. Possible values are:

  • integrate: The sample values are integrated over time.

  • normal: The sensor is operating in normal mode.

  • off: The sensor is not in use.

Enum: "off" "normal" "integrate"
scale
number (configLocalSensorNameChannelScale)

The scale value by which an A/D converter sample is to be divided to convert a sample to a physical quantity (the bias value is added to the sample before the scale is applied).

Responses
200

Normal response.

401

Unauthorized response.

post/config/local/sensor/{name}/channel
Request samples
application/json
{ }
Response samples
application/json
{
  • "status": "OK",
  • "error": "Error message (present if an error occurred)."
}

Delete /config/local/sensor/{name}/channel

Reset channel to default configuration.

SecurityApiKey
Request
path Parameters
name
required
string

The name of a sensor (L1-L3, Ldc, or S1-S30).

Example: S1
Responses
200

Normal response.

401

Unauthorized response.

delete/config/local/sensor/{name}/channel
Request samples
Response samples
application/json
{
  • "status": "OK",